About us

Runway



RUNWAY PHYSICAL CHARACTERISTICS

RWY designator

GEO BRG

(DEG)

Dimensions of RWY (M)

Strength (PCN) and surface of RWY and SWY

THR COORD
RWY end COORD
THR GUND

THR ELEV and
highest ELEV of TDZ of precision APP RWY

1

2

3

4

5

6

12121.923400 x 453000 M: PCN 65/F/C/X/T ASPH
400 M: PCN 60/R/C/W/T CONC
444935.47N
0201727.49E
444837.22N
0201938.83E
142 FT

THR 317 FT
TDZ 328 FT

30301.943400 x 45400M: PCN 60/R/C/W/T CONC
3000 M: PCN 65/F/C/X/T ASPH
444844.06N
0201923.40E
444935.47N
0201727.49E
142 FT

THR 333 FT
TDZ 335 FT


RWY designator

Slope of RWY-SWY

SWY dimensions (M)

CWY dimensions (M)

Strip dimensions (M)

OFZ

1

7

8

9

10

11

12+0.4% (580M), +0.2% (1660M),
-0.2% (270M), 0% (370M),
-0.2% (120M), 0% (400M)
NILNIL3520 x 300Yes
300% (400M), +0.2% (120M),
0% (370M), +0.2% (270M),
-0.2% (1660M), -0.4% (580M)
NILNIL3520 x 300NIL
12Remarksa) RWY 12 - Precision approach CAT I/II/III
RWY 30 - Precision approach CAT I
b) RWY shoulders 7.5 M paved

DECLARED DISTANCES



RWY designator

TORA (M)

TODA (M)

ASDA (M)

LDA (M)

Remarks

1

2

3

4

5

6

123400340034003400NIL
12280028002800Take-off from intersection with TWY C
303400340034003000NIL
30300030003000-Take-off from intersection with TWY E
30208520852085-Take-off from intersection with TWY D

APPROACH AND RUNWAY LIGHTING

RWY designator

APCH LGT type
LEN
INTST

THR LGT colour WBAR

VASIS
(MEHT)
PAPI

TDZ
LGT
LEN

RWY CL LGT LEN spacing colour, INTST

RWY edge LGT LEN spacing colour, INTST

RWY end LGT colour WBAR

SWY LGT LEN (M) colour

1

2

3

4

5

6

7

8

9

12CAT II/III1)
900 M
LIH

GRN
GRN

PAPI
Both/3°
(72 FT)
900 M3400 M
15 M
W: 2500 M
R/W: FM 2500 M to 3100 M
R: FM 3100 M
LIH
3400 M
60 M
W YCZ 600 M
LIH
RED
-
NIL
30CAT I
900 M
LIH

GRN
GRN

PAPI
Both/3°
(62 FT)
NIL3000 M
15 M
W: 2100 M
R/W: FM 2100 M to 2700 M
R: FM 2700 M
LIH
3000 M
60 M
W YCZ 600 M2)
LIH
RED
-
NIL

10

Remarks

1) With sequenced flashing lights from 900 M up to 300 M before THR
2) Red between beginning of RWY and displaced THR (400 M)

OTHER LIGHTING, SECONDARY POWER SUPPLY


1ABN / IBN location, characteristics and hours of operationNIL
2LDI location and LGT Anemometer location and LGTLDI: NIL
Anemometer: See AD Chart - ICAO for location; lighted
3TWY edge and centre line lightingEdges: NIL
Centre line: TWY A, B, C, D, E, F, G (up to ACFT stand A10), H (up to ACFT stand B1) and J
4Secondary power supply / switch-over timeAvailable / switch-over time 10 SEC for CAT I, 1 SEC for CAT II/III
5RemarksWDI: See AD Chart - ICAO