menu

Runway

RUNWAY PHYSICAL CHARACTERISTICS

 RWY designator  GEO BRG (DEG) Dimensions of RWY (M)  Strength (PCN) and surface of RWY and SWY  THR COORD
RWY end COORD
THR GUND
THR ELEV and
highest ELEV of TDZ of precision APP RWY

1

2

3

4

5

6

12 121.92 3400 x 45 3000 M: PCN 65/F/C/X/T ASPH
400 M: PCN 60/R/C/W/T CONC
444935.47N
0201727.49E
444837.22N
0201938.83E
142 FT

THR 317 FT
TDZ 328 FT

30 301.94 3400 x 45 400M: PCN 60/R/C/W/T CONC
3000 M: PCN 65/F/C/X/T ASPH
444844.06N
0201923.40E
444935.47N
0201727.49E
142 FT

THR 333 FT
TDZ 335 FT


RWY designator Slope of RWY-SWY SWY dimensions (M) CWY dimensions (M) Strip dimensions (M) OFZ

1

7

8

9

10

11

12 +0.4% (580M), +0.2% (1660M),
-0.2% (270M), 0% (370M),
-0.2% (120M), 0% (400M)
NIL NIL 3520 x 300 Yes
30 0% (400M), +0.2% (120M),
0% (370M), +0.2% (270M),
-0.2% (1660M), -0.4% (580M)
NIL NIL 3520 x 300 NIL
12 Remarks a) RWY 12 - Precision approach CAT I/II/III
RWY 30 - Precision approach CAT I
b) RWY shoulders 7.5 M paved

DECLARED DISTANCES

RWY designator TORA (M) TODA (M) ASDA (M) LDA (M) Remarks
1 2 3 4 5 6
12 3400 3400 3400 3400 NIL
12 2800 2800 2800   Take-off from intersection with TWY C
30 3400 3400 3400 3000 NIL
30 3000 3000 3000 - Take-off from intersection with TWY E
30 2085 2085 2085 - Take-off from intersection with TWY D

APPROACH AND RUNWAY LIGHTING

RWY designator

APCH LGT type
LEN
INTST

THR LGT colour WBAR

VASIS
(MEHT)
PAPI

TDZ
LGT
LEN

RWY CL LGT LEN spacing colour, INTST

RWY edge LGT LEN spacing colour, INTST

RWY end LGT colour WBAR

SWY LGT LEN (M) colour

1

2

3

4

5

6

7

8

9

12 CAT II/III1)
900 M
LIH

GRN
GRN

PAPI
Both/3°
(72 FT)
900 M 3400 M
15 M
W: 2500 M
R/W: FM 2500 M to 3100 M
R: FM 3100 M
LIH
3400 M
60 M
W YCZ 600 M
LIH
RED
-
NIL
30 CAT I
900 M
LIH

GRN
GRN

PAPI
Both/3°
(62 FT)
NIL 3000 M
15 M
W: 2100 M
R/W: FM 2100 M to 2700 M
R: FM 2700 M
LIH
3000 M
60 M
W YCZ 600 M2)
LIH
RED
-
NIL

10

Remarks

1) With sequenced flashing lights from 900 M up to 300 M before THR
2) Red between beginning of RWY and displaced THR (400 M)

OTHER LIGHTING, SECONDARY POWER SUPPLY

1 ABN / IBN location, characteristics and hours of operation NIL
2 LDI location and LGT Anemometer location and LGT LDI: NIL
Anemometer: See AD Chart - ICAO for location; lighted
3 TWY edge and centre line lighting Edges: NIL
Centre line: TWY A, B, C, D, E, F, G (up to ACFT stand A10), H (up to ACFT stand B1) J and M
4 Secondary power supply / switch-over time UPS for CAT I/II/III
5 Remarks WDI: See AD Chart - ICAO

Temperature
28°C
Air pressure
1013mB
Wind
4.63m/s